Atomic Absorption Spectrophotometer TRAS-701is completely controlled by a computer. It has a fully automatic control system with advanced temperature control technology of a graphite furnace. With a wavelength range of 190 to 900 nm. Providing a spectral bandwidth of 0.1, 0.2, 0.4, 1.0, and 2.0 nm. The setting of the background deduction method. The fast heating capacity can improve the elements' flexibility even more. . It presents the hollow cathode lamp in its operational state. It is a safe, dependable, and convenient flame system with a multi-functional software workstation.
Wavelength range | 190 to 900 nm |
---|---|
Spectral bandwidth | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
Accuracy of the wavelength | ±0.15 nm |
Receptivity of the wavelength | ≤0.04 nm |
Baseline stability | ≤0.002A/30 min (Cu) |
Characteristic viscosity | 0.02 μg/ml/1% (Cu) |
Checking limit | 0.004 μg/ml (Cu) |
Preciseness | 0.005 |
Grating | 1800 lines/ mm |
Inflamer | All-metal titanium burner |
Atomizer | Effective glass atomizer |
Lamp stand | 8 |
D2 background correction ability | When the background is 1 A, the background ability should be deducted not less than 50 times, self-absorption background deduction method |
Size | 700 mm×550 mm×450 mm |
weight | 75 Kg |
Power source | 220V±22V AC |
Flame System | 100 mm, ≤0.006 A/30 min, ≤0.025 μg/ml/1%, ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008 μg/ml), Can Automatically cut off the gas when The pressure is not enough, The power is off, flameout and unconformity of the burner. |
Graphite furnace | 3000 ℃, ≥2000 ℃/S, Cd≤0.5×10 to12 g Cu≤0.5×10 to 11 g, Cu≤3% Cd≤3 %, 550 mm×450 mm×300 mm 65 Kg |
Power source and power | 220 V±22 V AC 7000 W |
• The hollow cathode lamp's operational state
• Wavelength searching and peak search are completely automatic
• The integrated floated optical platform design improves the optical system's shock resistance and stability when using the optical signal for an extended period
• Eight light stands can be changed automatically while simultaneously preheating and optimizing the eight lights
• Adjustable position: It can automatically set the front and rear positions, as well as the best height for the flame burner
• The setting of the background deduction method
• Background self-absorption and the Deuterium lamp
• Data processing, super-strong database with over 500 data self-storage and cut-off storage functions
• can hold the analysis results in form of a Spreadsheet, and the test procedure and result can be called at random
• The flame results demonstrated and the emissions technique are two methods for measuring
• Result printing: parameter printing, data result printing, and diagram printing
• It has fully automatic controlled, with the help of the software
• The selection of lamp elements, Front-to-rear lifter adjustment (up/down)
• Re-adjustment of optical energy, selecting the slit, Determination of wavelength scanning and peak searching, sixth, choosing an atomizer
• Full safety chain protection, warning and automatic protection against incorrect burner, gas leakage, air under voltage, and abnormal flameout
• Managing the flow of gas
• Auto-flaming and extinguishing
• Temperature control technology of graphite furnace advanced
• Introducing PID technology can effectively overcome the influence on the temperature rising procedure
• The combination of the 3ms/time fast sampling technique can result in more accurate and dependable testing data
• The fast heating capacity can improve the elements' flexibility even more
• Use a standard 220V power source instead of a 380V dynamic power source
• The maximum procedure heating capacity setting of 20 levels can make testing multiple samples more efficient and comfortable
• Three grades of adjustable gas flow can be tailored to meet a variety of application requirements
• Can provide a timely warning when the gas and water are turned off and there is insufficient gas and water, thereby avoiding equipment damage and measurement error
• Safe, reliable, and convenient flame system
• EPC can more precisely control the flow of acetylene (C2H2) and is a type of system that is also simple to operate
• A well-functioning Tomi Ziti on the system allows for greater sensitivity
• The entire operating system is highly secure because the fire safety system scan alert for the fluctuation
• It will also automatically turn off the gas and prohibit temper tantrums
• Protects the operating personnel and equipment from harm and damage
• Multi-functional software workstation, a working computer that is supported WINDOWS XP/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000
• The extensive menu makes it easy for customers to use
• Easy conversion between different menus simplifies the operation
• A variety of analytical correction methods gives users more options
• The basic default parameter settings allow even inexperienced users to perform routine operations
• Flexible storage, editing, and printing methods provide the most support to the user